Meca500 R3 EMC test results#

Table 14 lists all the tests passed by the Meca500 R4, called by the harmonized standards related to electromagnetic compatibility.

Table 14 Summary of EMC test results for the Meca500 R4#

Test Name / Standards

Test specifications

MPCR

Result

Conducted Emissions
FCC part 15 (2018) subpart B
Class A
150kHz–30MHz

n/a

Pass

Radiated Emissions
FCC part 15 (2018) subpart B
Class A
30MHz–5GHz

n/a

Pass

Conducted Emissions
CISPR11 (2015) A1 (2016)
Group 1 - class A
150kHz–30MHz

n/a

Pass

Radiated Emissions
CISPR11 (2015) A1 (2016)
Group 1 - class A
30MHz–1GHz

n/a

Pass

Conducted Emissions
ICES-003 (2016)
Class A
150kHz–30MHz

n/a

Pass

Radiated Emissions
ICES-003 (2016)
Class A
30MHz–5GHz

n/a

Pass

Electrostatic Discharge Immunity
IEC61000-4-2 (2008)
Contact: ±4kV
Air: ±8kV

B

Pass

Radiated Electromagnetic Field Immunity
IEC61000-4-3 (2006) A1 (2007) A2 (2010)
80MHz–1000MHz: 10V/m
1.4GHz–6GHz: 3V/m
2GHz–2.7GHz: 1V/m

A

Pass

Electrical Fast Transient Immunity
IEC61000-4-4 (2012)
Power: ±2kV / 5kHz
I/O Ports: ±1kV / 5kHz
Communication Ports: ±1kV / 5kHz

B

Pass

Surge Immunity
IEC61000-4-5 (2014)
Power: ±2kV L-PE / ±1kV L-L
I/O Ports: N/A
Communication Ports: N/A

B

Pass

Immunity to Conducted Disturbances,
Induced by Radio-Frequency Fields
IEC61000-4-6 (2013)
Power: 3V
I/O Ports: 3V
Communication Ports: 3V

A

Pass

Power Frequency Magnetic Field Immunity
IEC61000-4-8 (2009)

Continuous Field: 30A/m / 50Hz & 60Hz

A

Pass

Voltage Dips, Short Interruptions and Voltage Variation Immunity on AC Input
IEC61000-4-11 (2004)
Voltage dips:
    0% Un during 1 cycle
    40% Un during 10 cycles (at 50Hz)
    40% Un during 12 cycles (at 60Hz)
    70% Un during 25 cycles (at 50Hz)
    70% Un during 30 cycles (at 60Hz)
Short interruptions:
    0% Un during 250 cycles (at 50Hz)
    0% Un during 300 cycles (at 60Hz)

B
C
C
C
C

C
C

Pass

Minimum performance criterion required