MCS500 EMC test results#
Table 12 lists all the tests passed by the MCS500, called by the harmonized standards related to electromagnetic compatibility.
Test Name / Standards |
Test specifications |
MPCR† |
Result |
|---|---|---|---|
Conducted Emissions
FCC part 15 subpart B (2022)
|
Class A
150kHz–30MHz
|
n/a |
Pass |
Radiated Emissions
FCC part 15 subpart B (2022)
|
Class A
30MHz–6GHz
|
n/a |
Pass |
Conducted Emissions
ICES-001 Issue 5 (2020)
|
CSA CISPR 11:19 Group 1 – class A
150kHz–30MHz
|
n/a |
Pass |
Radiated Emissions
ICES-001 Issue 5 (2020)
|
CSA CISPR 11:19 Group 1 – class A
30MHz–1GHz
|
n/a |
Pass |
Conducted Emissions
CISPR 11 (2015) A1 (2016) A2 (2019)
|
Group 1 – class A
150kHz–30MHz
|
n/a |
Pass |
Radiated Emissions
CISPR 11 (2015) A1 (2016) A2 (2019)
|
Group 1 – class A
30MHz–6GHz
|
n/a |
Pass |
Harmonic Current Emission Limits
EN 61000-3-2 (2019) A1 (2021)
|
N/A for Class A equipment |
n/a |
n/a |
Voltage Fluctuations and Flicker Limitations
EN 61000-3-3 (2013) A1 (2019) A2 (2021)
|
N/A for Class A equipment |
n/a |
n/a |
Electrostatic Discharge Immunity
IEC 61000-4-2 (2008)
|
Contact: ±4kV
Air: ±2kV, ±4kV, ±8kV
|
B |
Pass |
Radiated Electromagnetic Field Immunity
IEC 61000-4-3 (2020)
|
80MHz–1000MHz: 3V/m
1.4GHz–3GHz: 3V/m
3GHz–6GHz: 3V/m
|
A |
Pass |
Electrical Fast Transient Immunity
IEC 61000-4-4 (2012)
|
Power: ±2kV / 5kHz & 100kHz
I/O Ports: N/A
Communication Ports: ±1kV / 5kHz & 100kHz
|
B |
Pass |
Surge Immunity
IEC 61000-4-5 (2014) A1 (2017)
|
Power: ±2kV L-PE / ±1kV L-L
I/O Ports: N/A
Communication Ports: N/A
|
B |
Pass |
Immunity to Conducted Disturbances,
Induced by Radio-Frequency Fields
IEC 61000-4-6 (2013)
|
Power: 3V
I/O Ports: N/A
Communication Ports: 3V
|
A |
Pass |
Power Frequency Magnetic Field Immunity
IEC 61000-4-8 (2009)
|
Continuous Field: 30A/m / 50Hz & 60Hz |
A |
Pass |
Voltage Dips, Short Interruptions and
Voltage Variation Immunity on AC Input
IEC 61000-4-11 (2020)
|
Voltage dips:
0% Un during half cycle
0% Un during 1 cycle
40% Un during 10 cycles (at 50Hz)
40% Un during 12 cycles (at 60Hz)
70% Un during 25 cycles (at 50Hz)
70% Un during 30 cycles (at 60Hz)
Short interruptions:
0% Un during 250 cycles (at 50Hz)
0% Un during 300 cycles (at 60Hz)
|
B
B
C
C
C
C
C
C
|
Pass |
† Minimum performance criterion required