MCS500 EMC test results#

Table 12 lists all the tests passed by the MCS500, called by the harmonized standards related to electromagnetic compatibility.

Table 12 Summary of EMC test results for the MCS500#

Test Name / Standards

Test specifications

MPCR

Result

Conducted Emissions
FCC part 15 subpart B (2022)
Class A
150kHz–30MHz

n/a

Pass

Radiated Emissions
FCC part 15 subpart B (2022)
Class A
30MHz–6GHz

n/a

Pass

Conducted Emissions
ICES-001 Issue 5 (2020)
CSA CISPR 11:19 Group 1 – class A
150kHz–30MHz

n/a

Pass

Radiated Emissions
ICES-001 Issue 5 (2020)
CSA CISPR 11:19 Group 1 – class A
30MHz–1GHz

n/a

Pass

Conducted Emissions
CISPR 11 (2015) A1 (2016) A2 (2019)
Group 1 – class A
150kHz–30MHz

n/a

Pass

Radiated Emissions
CISPR 11 (2015) A1 (2016) A2 (2019)
Group 1 – class A
30MHz–6GHz

n/a

Pass

Harmonic Current Emission Limits
EN 61000-3-2 (2019) A1 (2021)

N/A for Class A equipment

n/a

n/a

Voltage Fluctuations and Flicker Limitations
EN 61000-3-3 (2013) A1 (2019) A2 (2021)

N/A for Class A equipment

n/a

n/a

Electrostatic Discharge Immunity
IEC 61000-4-2 (2008)
Contact: ±4kV
Air: ±2kV, ±4kV, ±8kV

B

Pass

Radiated Electromagnetic Field Immunity
IEC 61000-4-3 (2020)
80MHz–1000MHz: 3V/m
1.4GHz–3GHz: 3V/m
3GHz–6GHz: 3V/m

A

Pass

Electrical Fast Transient Immunity
IEC 61000-4-4 (2012)
Power: ±2kV / 5kHz & 100kHz
I/O Ports: N/A
Communication Ports: ±1kV / 5kHz & 100kHz

B

Pass

Surge Immunity
IEC 61000-4-5 (2014) A1 (2017)
Power: ±2kV L-PE / ±1kV L-L
I/O Ports: N/A
Communication Ports: N/A

B

Pass

Immunity to Conducted Disturbances,
Induced by Radio-Frequency Fields
IEC 61000-4-6 (2013)
Power: 3V
I/O Ports: N/A
Communication Ports: 3V

A

Pass

Power Frequency Magnetic Field Immunity
IEC 61000-4-8 (2009)

Continuous Field: 30A/m / 50Hz & 60Hz

A

Pass

Voltage Dips, Short Interruptions and
Voltage Variation Immunity on AC Input
IEC 61000-4-11 (2020)
Voltage dips:
    0% Un during half cycle
    0% Un during 1 cycle
    40% Un during 10 cycles (at 50Hz)
    40% Un during 12 cycles (at 60Hz)
    70% Un during 25 cycles (at 50Hz)
    70% Un during 30 cycles (at 60Hz)
Short interruptions:
    0% Un during 250 cycles (at 50Hz)
    0% Un during 300 cycles (at 60Hz)

B
B
C
C
C
C

C
C

Pass

Minimum performance criterion required