2. Technical specifications#
Table 1 lists the main technical specifications for the MVK01 vacuum and I/O module.
Characteristics |
Value |
|---|---|
Compressed air connector |
port IN |
Control valve state |
Normally closed |
Operating input pressure |
2 bar to 8 bar |
Optimal input pressure |
7 bar |
Vacuum connector |
port VAC |
Maximum vacuum |
−75 kPa |
Pressure sensor accuracy |
±1.5 kPa |
Suction rate (max.) |
37.5 l/min |
Air consumption suction |
23.5 l/min |
Maximum for inputs |
24 V (DC), 10 mA |
Minimum for inputs |
3.3 V (DC), 1.1 mA |
Maximum for outputs |
24 V (DC), 250 mA |
Ports |
Three M5 threaded orifices, of which port IN comes with preinstalled push-in pneumatic fitting for 6-mm OD tubes, port VAC comes with preinstalled push-in pneumatic fitting for 4-mm OD tubes, and port EXH comes with a preinstalled pneumatic muffler. |
Mechanical adjustments |
Screw for adjusting the force of the air purging (marked ADJ) |
Housing |
Black anodized aluminum alloy |
Total weight |
572 g |
Sound level free |
72 dB (A) |
Sound level suction |
62 dB (A) |
Operating temperature |
5°C to 45°C |
Operating humidity |
[10%, 80%] (non-condensing) |
Figure 3 presents the generated vacuum at different input pressures.
Note
To prevent the module from malfunctioning, please ensure that compressed air is supplied within the specified limits, as detailed in Table 1.
Figure 3 Achievable vacuum at various input pressures#
Figure 4 presents the evacuation time at different vacuum levels.
Figure 4 Evacuation time at various vacuum levels#
Figure 5 shows the principal dimensions of the module.
Figure 5 MVK01 module dimensions#
Note
You can download the CAD file of the MVK01 pneumatic module from here.