SetNetworkOptions#
This command is used to set persistent parameters affecting the network connection. The new parameter values will take effect only after a robot reboot.
Syntax#
SetNetworkOptions(n)
Arguments#
n: an integer ranging from 0 to 60 that defines the TCP keep-alive connection timeout in seconds, specifying how long the robot waits for client replies before terminating the connection; setting this value to 0 disables the keep-alive feature entirely, which may result in significantly delayed detection of connection failures.
Note
Instead of using the keep-alive timeout for detecting a lost connection, it is recommended to use
ConnectionWatchdog which provide a much more
reliable and precise way of detecting communication issues with the robot.
Default values#
This setting is persistent and retained after a power cycle (a reboot).
The factory default is 3.
Usage restrictions#
This command can only be executed when the robot is deactivated.
Cyclic protocols#